jecsany@163.com      +86-13065600656    
You are here: Home » Products » Circuit Breakers & Switch » Isolate Switch » High Quality 36KV 1250A Porcelain Rotating Center Isolator with Mounting Structure
PRODUCT DETAIL

High Quality 36KV 1250A Porcelain Rotating Center Isolator with Mounting Structure

Share to:

  • Rotating Isolate
  • Jecsany
  • Porcelain
  • 10
  • IEC-60265, IEC-129
  • 1250A
  • 38KV
Quantity:


Standard

 IEC/IEEE and DVE-recommendation standards especially comply with DIN VDE 0670 part 

 IEC-60265, IEC-129

Features

 All steels are made of either in stainless steel or hot-dip galvanized steel.

 1. Solid and stable base frame.
 2. main contact with ice protection.
 3. Polymer insulators or alternatively in porcelain.
 4. Minimal sag for the line-connection between two fixed terminals.
 5. Completely maintence antirust Aluminium alloy Arc chamber.
 6. Switching-off procedure without external arc.
 7. Short circuit making capacity under specific conditions possible
 8. Fixing on the supporting structure either by clamping(free setting) or screwing (holes in the   base frame)
 9. Easy on-site installation and setting.

 10. High reliabilty up to 1000 cycles (depending on the running current).

 11. All contacts are either sliver or tin-plated.
 12. Practically maintance-free.

Environmental  Conditions

 Ambient Temperature: -30℃ - +40℃ 

 Altitude: 3000m

 Frequency: 50Hz / 60Hz

 Maximum Wind Speed: 35m/s


 

Type
  UnitGW4-35/630GW4-35/1250
Rated VoltageKV3535
Rated CurrentA6301250
FrequencyHz50/6050/60
Impulse Voltage (BIL)KV150150
Power Frequency withstand VoltageKV5050
Creepage DistanceMM11001100
WeightKGS282282
Package SizeCM128*93*95128*93*95


Isolating Switch 

An electrical device for the reliable disconnection of certain sections of a high-voltage electrical network when there is no current in them. The use of isolating switches (either alone or in combination with high-speed short-circuiting devices) makes it possible to simplify the arrangement of switching points and transformer substations and to eliminate expensive high-voltage circuit breakers.


In the case of damage to certain sections of a network, the circuit breakers operate first, and then the isolating switches automatically disconnect the damaged section, after which the circuit breakers close again and restore electric power to the rest of the consumers on the network. Isolating switches are also used to disconnect and reconnect unloaded transformers and sections of power lines during operation. An isolate switch must provide a reliable connection in case of a random occurrence of a short circuit in the network. An important characteristic of an isolating switch is a short operate time, particularly the disconnect time, which must not exceed 0.1 sec.