Home > Products > Fuse Cutouts

China Fuse Cutouts Factory

"JECSANY" is a professional China various medium and high voltage product provider which supplies Fuse Cutouts, surge Arrester and Protection Device, vacuum circuit breakers, auto reclosers, switchgear, polymer/porcelain insulators, power tools, power accessories, OPGW/ADSS, distribution transformers, etc. And be able to provide one-stop service for new and old customers, including product development, design, manufacturing, transportation, installation, and after-sales service.

Fuse Cutouts are the most commonly used short-circuit protection switch for branch lines and distribution transformers of 10kV-36KV distribution lines.
The drop-out fuse is installed on the branch line of 10kV-36KV distribution line, which can reduce the scope of power outage. Because it has an obvious disconnection point, it has the function of isolating switch, which creates a safe working environment for the lines and equipment in the maintenance section.
Installed on the distribution transformer, it can be used as the main protection of the distribution transformer.
It has the characteristics of economy, easy operation and strong adaptability to outdoor environment. It is widely used in 10kV-36KV distribution lines and the primary side of distribution transformers as protection and equipment switching and switching operations, and has been popularized.
The working principle of the drop-out fuse can be summarized as follows:
The moving contacts at both ends of the fuse tube are fastened by the fuse (melt), and after the upper moving contact is pushed into the "duckbill" protruding part, the upper static contact made of phosphor copper sheet is pressed against the upper moving contact. head, so the fuse tube is firmly stuck in the "duckbill". When the short-circuit current is blown through the fuse, an arc is generated, and the steel paper tube lined with the fuse tube generates a large amount of gas under the action of the arc. Because the upper end of the fuse tube is sealed, the gas is ejected to the lower end to blow out the arc. Because the fuse is blown, the upper and lower moving contacts of the fuse tube lose the tightening force of the fuse. Under the action of the fuse tube's own gravity and the spring sheets of the upper and lower static contacts, the fuse tube falls rapidly and the circuit is disconnected , remove the faulty section line or faulty equipment.

"JECSANY" Fuse Cutouts have stable quality and the products are exported to Southeast Asia, South Africa, South America, the Middle East and other global markets. OEM customization can also be made according to the drawings or samples provided by customers.
View as  
 
Expulsion Dropout 22kv T Bar Type Fuse Cut Out

Expulsion Dropout 22kv T Bar Type Fuse Cut Out

Model:DOPT22360
The primary purpose of any Expulsion Dropout 22kv T Bar Type Fuse Cut Out is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
12KV 100A Dropout Fuse

12KV 100A Dropout Fuse

Model:DOF12100C320
The primary purpose of any 12KV 100A Dropout Fuse is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
35kV Polymer T bar Load Break Fuse Cutout

35kV Polymer T bar Load Break Fuse Cutout

Model:LBF35100C1080T
The primary purpose of any 35kV Polymer T bar Load Break Fuse Cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
35kV Polymer Load Break Fuse Cutout

35kV Polymer Load Break Fuse Cutout

Model:LBF35100C1080
The primary purpose of any 35kV Polymer Load Break Fuse Cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
24kV Silicon Rubber Load Break Fuse Cutout with Arc Chute

24kV Silicon Rubber Load Break Fuse Cutout with Arc Chute

Model:LBF24200C660
The primary purpose of any 24kV Silicon Rubber Load Break Fuse Cutout with Arc Chute is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
24kV 100A Load Break Fuse Cutout with Arc Chute

24kV 100A Load Break Fuse Cutout with Arc Chute

Model:LBF24100C600
The primary purpose of any 24kV 100A Load Break Fuse Cutout with Arc Chute is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
15kV Double column Polymer Fuse Cutout

15kV Double column Polymer Fuse Cutout

Model:JVDOF15100
The primary purpose of any 15kV Double column Polymer Fuse Cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
24kV Polymer T Bar Type Fuse Cutout

24kV Polymer T Bar Type Fuse Cutout

Model:JDOS24100C760T
The primary purpose of any T Bar type 24kV Polymer T Bar Type Fuse Cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. T Bar type Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
24kV Silicon Rubber T Bar Type Fuse Cutout

24kV Silicon Rubber T Bar Type Fuse Cutout

Model:JDOS24100C600T
The primary purpose of any T Bar type 24kV Silicon Rubber T Bar Type Fuse Cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. T Bar type Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
24kV 100A Polymer Dropout Fuse

24kV 100A Polymer Dropout Fuse

Model:JDOS24100C600
The primary purpose of any 24kV 100A Polymer Dropout Fuseis to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
38KV 100A Polymer Dropout Fuse

38KV 100A Polymer Dropout Fuse

Model:JDOS381C1350
The primary purpose of any 38KV 100A Polymer Dropout Fuse is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Polymer Dropout Fuse provides reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
36kV Silicon Rubber Dropout Fuse Cutout

36kV Silicon Rubber Dropout Fuse Cutout

Model:JDOS351C970
The primary purpose of any 36kV Silicon Rubber Dropout Fuse Cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Read MoreSend Inquiry
Jecsany is one of the professional Fuse Cutouts manufacturers and suppliers in China. Welcome to buy newest cheap Fuse Cutouts from our factory. our products are high quality and latest selling, IEC, we are happy to provide you with a low price quotation.