Home > Products > Arrester and Protection Device > Line Protection Device > MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV
MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV
  • MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KVMLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV

MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV

Model:MLPD10-I
Welcome to buy MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV from Jecsany. Every request from customers is being replied within 24 hours.

Model:MLPD10-I

Send Inquiry    PDF DownLoad

Product Description

Professional China MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV Manufacturers and Suppliers. Jecsany is a MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV manufacturer and supplier in China.

Specification

1.Highest voltage for equipment can be up to 13 kV.
2.Protects from Induced Overvoltage
3.No maintenance is required
4.No special grounding required
5.Protection against: IOV
6.Only 1 product per pole is required
7.Products are installed with phase alternation (А -> B -> C)

8.Definitely great use and the highest possible reliability

9.Line Protection Device has been designed to ensure the most effective protection from indirect strokes. This device is able to perform as highly effective lightning protection system, providing secure power network operation in 80% of such issues.
10.In order to protect sensitive equipment, such as pole-mounted transformers (PMT), conventional metal oxide surge arresters still must be used


Operational Principle
1.Ensuring a high ability to discharge excessive energy of an overvoltage in the surrounding atmosphere
2.The induced overvoltage will create an electrical power arc between the terminal electrode of a MLPD and the conductor clamp on a line. First, the arc will be divided into a series of small arcs by a series of discharge chambers, and then quickly extinguished when the oscillating current of the grid exceeds zero.
3.Make full use of the grounding resistance between two towers, each tower only needs to install one product
4.It is used for the protection of overhead line induced lightning overvoltage, which is more cost-effective than traditional solutions.


Parameters

Description Unit Value
Electrical line parameters    
Highest voltage for equipment ⑴  kV 13
Maximum prospective fault current kA 1,5
External air gap mm 50±10
50% flashover voltage kV 85
Power frequency withstand voltage ⑵ kV (wet/dry) 20/30
Lightning parameters    
Lightning discharge capability  (200 μs) ⑶  C 1.0
High current impulse (4/10 μs) kA 65
Nominal discharge current kA 20
General Parameters    
Additional power losses on the line % 0
Average expected lifespan years 20
UV resistance ⑷  h 1000
Weight kg 1.0
Maintenance   1 visual verification per year

⑴ According to IEC 60038, ⑵ According to IEC 60071-1, ⑶ According to  IEC 60099-8, ⑷ According to ISO 4892-2, method A, IEC 62217

Size



Installation

Pin/post/pin-post


Hot Tags: MLPD10-I Multi-chamber Arc Blowing Type Line Protection Device 10KV, China, Manufacturers, Suppliers, Factory, Cheap, Low Price, IEC, Newest, Quality, Latest Selling

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept