The 33KV Load Break Outdoor Fuse Cutout with Arc Chute is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Model:LBFCO33660

Send Inquiry    PDF DownLoad

Product Description


Principle and Function of 33KV Load Break Outdoor Fuse Cutout with Arc Chute


The high-voltage drop-out fuse consists of three parts: insulating support, dynamic and static contacts, and fuse tube. The static contacts are installed at both ends of the insulating support, and the fuse tube is composed of an inner arc suppression tube and an outer phenolic paper tube or epoxy glass fiber cloth tube.

Drop-out fuses are suitable for power systems with a frequency of 50/60Hz and a rated voltage of 35KV and below, and are installed on the high-voltage side of distribution transformers or on the main lines of distribution. The main function is where the protection performance is not high, it can be used in conjunction with the isolating switch to replace the automatic air switch; it can also be used in conjunction with the load switch to replace the expensive circuit breaker. It also has short circuit protection, overload and isolation circuits.

Product Parameter (Specification)


Type Unit LBFCO33660 LBFCO33660
Rated Voltage KV 36 36
Rated Current A 100 200
Rated Short-circuit Breaking Current KA 8 8
Impulse Withstand Voltage (BIL) KV 170 170
Power Frequency withstand Voltage KV 70 70
Creepage Distance mm 660 660
Weight kg 12.2 12.8
Applicable Standard   IEC 60282-2 IEC 60282-2
Package Size cm 61.5*41.5*18.5 61.5*41.5*18.5

Product Details



Application of Cutouts


More Products








Hot Tags: 33KV Load Break Outdoor Fuse Cutout with Arc Chute, China, Manufacturers, Suppliers, Factory, Cheap, Low Price, IEC, Newest, Quality, Latest Selling

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept