Model:YH5W-3
M.V. 3KV 5kA Polymer Metal Oxide Lightning Arrester are used to protect transformers and other equipments in station and distribution systems against the damage by atmospheric (especially lightning effects) and operational conditions.
Metal oxides Lightning arresters without gaps are designed to prevent probable damages in the case of typical surges in energy systems while it has no negative effect on energy systems in normal operation voltage. This special feature of gapless arresters originating from non-linear characteristics of metal-oxide varistors between voltage and current scales. The non-linear feature is much higher compared to silicon carbide Lightning arresters.
Model:Y10W-36
M.V. 36KV 10KA Porcelain Lightning Arrester are used to protect transformers and other equipments in station and distribution systems against the damage by atmospheric (especially lightning effects) and operational conditions.
Metal oxides surge arresters without gaps are designed to prevent probable damages in the case of typical surges in energy systems while it has no negative effect on energy systems in normal operation voltage. This special feature of gapless arresters originating from non-linear characteristics of metal-oxide varistors between voltage and current scales. The non-linear feature is much higher compared to silicon carbide surge arresters.
Model:Y10W-30
M.V. 30KV 10KA Porcelain Lightning Arrester are used to protect transformers and other equipments in station and distribution systems against the damage by atmospheric (especially lightning effects) and operational conditions.
Metal oxides surge arresters without gaps are designed to prevent probable damages in the case of typical surges in energy systems while it has no negative effect on energy systems in normal operation voltage. This special feature of gapless arresters originating from non-linear characteristics of metal-oxide varistors between voltage and current scales. The non-linear feature is much higher compared to silicon carbide surge arresters.
Model:Y5W-11
M.V. 11KV 5kA Porcelain Gapless Surge Arrester are used to protect transformers and other equipments in station and distribution systems against the damage by atmospheric (especially lightning effects) and operational conditions.
Metal oxides surge arresters without gaps are designed to prevent probable damages in the case of typical surges in energy systems while it has no negative effect on energy systems in normal operation voltage. This special feature of gapless arresters originating from non-linear characteristics of metal-oxide varistors between voltage and current scales. The non-linear feature is much higher compared to silicon carbide surge arresters.
Model:Y5W-9
M.V. Porcelain Metal Oxide Surge Arrester are used to protect transformers and other equipments in station and distribution systems against the damage by atmospheric (especially lightning effects) and operational conditions.
Metal oxides surge arresters without gaps are designed to prevent probable damages in the case of typical surges in energy systems while it has no negative effect on energy systems in normal operation voltage. This special feature of gapless arresters originating from non-linear characteristics of metal-oxide varistors between voltage and current scales. The non-linear feature is much higher compared to silicon carbide surge arresters.